KAD/EXC/101

Download Data Sheet
  • Overview
  • Specifications
  • Downloads
  • Featured Products
  • Request a Quote
  • Product Support

Each of the KAD/EXC/101’s 10 single ended excitation outputs has a programmable output voltage within the range of 0 to 24V.

There are three types of output available on the KAD/EXC/101: one output with a current limit up to 300mA (at 24V); one output with a current limit up to 50mA (at any output voltage); and the other eight outputs each with a current limit up to 15mA (at any output voltage). The current limit on each output type is programmable.

In addition to a programmable current limit, the first output type has a fixed, fold-back current limiter. This prevents the dissipating of too much power on the internal regulating element in case an output voltage is set lower than 24V.

Once a channel is overloaded (that is, the programmed current limit or the channel 0 fold-back limit is exceeded), the channel trips (automatically switches off).

The KAD/EXC/101 provides status of individual channels: information which channel has reached current limit and which has tripped. Additionally status of main internal power supply is provided.

Features

  • 10 single ended excitation outputs with programmable output voltage and current limit per channel
  • Total current drawn from all channels up to 300mA
  • One channel with a current limit up to 300mA at 24V (fold-back characteristics)
  • One channel with a current limit up to 50mA
  • Eight channels each with a current limit up to 15mA

Applications

  • Power source for external sensors
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Download Data Sheet